KLEMENS PULSERS
FREQUENCY, GAUSS & WATTAGE COMPARISONS
FREQUENCY, GAUSS & WATTAGE COMPARISONS
WAVE SHAPE
Klemens pulsers produce a square wave.
Klemens pulsers produce a square wave.
Unit Tesla Gauss per pulse Gauss per minute
Spectrum high range 2.465 24,650 4,437,000
Spectrum low range 0.021 210 10,500
Ultra Pulsa 2.1733 21,733 3,216,484
Super P 2.1733 21,733 1,999,436
Super T 0.425 4,256 319,200
GAUSS (INTENSITY MEASUREMENTS)
Klemens Super T Pulser
0.425T or 4256 Gauss each pulse
Total gauss produced in one second 319,200
Klemens Super P Pulser
2.1733T or 21,733 Gauss each pulse
Total gauss produced in one second 1,999,436
Klemens Ultra Pulsa
2.1733T or 21,733 Gauss each pulse
Total gauss produced in one second 3,216,484
Klemens Spectrum Pulser Low range
0.021T or 210 Gauss each pulse
Total gauss produced in one second 10,500
Klemens Spectrum Pulser High range
2.465T or 24,650 Gauss each pulse
Total gauss produced in one second 4,437,000
The Klemens Pulser ranges require an huge power supply to generate this amount of power in just one second.
Over a 20 year period that we have been manufacturing PEMF units, we have found that the effectiveness of the units is not in the gauss but in the frequency of the pulse.
Klemens Super T Pulser
0.425T or 4256 Gauss each pulse
Total gauss produced in one second 319,200
Klemens Super P Pulser
2.1733T or 21,733 Gauss each pulse
Total gauss produced in one second 1,999,436
Klemens Ultra Pulsa
2.1733T or 21,733 Gauss each pulse
Total gauss produced in one second 3,216,484
Klemens Spectrum Pulser Low range
0.021T or 210 Gauss each pulse
Total gauss produced in one second 10,500
Klemens Spectrum Pulser High range
2.465T or 24,650 Gauss each pulse
Total gauss produced in one second 4,437,000
The Klemens Pulser ranges require an huge power supply to generate this amount of power in just one second.
Over a 20 year period that we have been manufacturing PEMF units, we have found that the effectiveness of the units is not in the gauss but in the frequency of the pulse.
FREQUENCIES of VARIOUS PEMF UNITS
(Pulses per hour if all units could run non-stop)
Beck DIY Pulser 1 pulse per 12.5 sec 300 p/h
Standard Pulser 1 pulse per 3.5 sec 1,028 p/h
Standard Pulser 1 pulse per 1 sec 3,600 p/h
Super T Pulser 65 pulses per sec 234,000 p/h
Super T Pulser (upgrade) 75 pulses per sec 270,000 p/h
Super P Pulser 92 pulses per sec 331,200 p/h
Klemens Ultra Pulsa (2017) 124 pulses per sec 446,400 p/h
Klemens Ultra Pulsa (2019) 148 pulses per sec 532,800 p/h
Klemens Spectrum (2020) 180 pulses per sec 648,000 p/h
(Pulses per hour if all units could run non-stop)
Beck DIY Pulser 1 pulse per 12.5 sec 300 p/h
Standard Pulser 1 pulse per 3.5 sec 1,028 p/h
Standard Pulser 1 pulse per 1 sec 3,600 p/h
Super T Pulser 65 pulses per sec 234,000 p/h
Super T Pulser (upgrade) 75 pulses per sec 270,000 p/h
Super P Pulser 92 pulses per sec 331,200 p/h
Klemens Ultra Pulsa (2017) 124 pulses per sec 446,400 p/h
Klemens Ultra Pulsa (2019) 148 pulses per sec 532,800 p/h
Klemens Spectrum (2020) 180 pulses per sec 648,000 p/h
Wattages of Klemens Pulsers
Eclipse - 188.3 watts
Spectrum - 103 watts
Ultra Pulsa - 105.25 watts
Equine Energiser - 105.25 watts
Super P - 73.29 watts
Super T - 53.6 watts
Contact
Klemens Pulsers
Phone: 61 7 4157 9962
Mobile: 61 407 257 453
31 Old Cedars Road
South Bingera Q 4670
email: [email protected]
ABN: 55 123 118 365
Klemens Pulsers
Phone: 61 7 4157 9962
Mobile: 61 407 257 453
31 Old Cedars Road
South Bingera Q 4670
email: [email protected]
ABN: 55 123 118 365